SonoSite Edge

sonosite-edge-ultrasound-machine
SonoSite Edge Ultrasound

Edge Technology

SonoHD2 Second Generation Imaging Technology- adaptive image clarity provides a new series of image enhancement algorithms that reduce speckle noise and image artifacts to give the EDGE ultrasound tool a new standard in point-of-care visualization image quality.

Below is a generalized description of this systems technology, specifications, features, and options. The below may not reflect the features and options available on units in our inventory.

SonoHD2™ Second Generation Imaging Technology
Adaptive image clarity provides a new series of image enhancement algorithms that reduce speckle noise and image artifacts to give the EDGE ultrasound tool a new standard in point-of-care visualization image quality.
SonoADAPT™ Tissue Optimization
Eliminates complicated manipulation of multiple controls.
SonoMB® Multi-beam Imaging
Increasing resolution of small structures and enhancing border delineation.
Advanced Needle Visualization
Aids needle visualization while maintaining striking image quality of the target and surrounding anatomy.
ColorHD™ Technology
Increases color performance, sensitivity and frame rates for more diagnostic information.

System Specifications

  • Weight: 8.5 lbs (3-85 kg) (with battery)
  • Dimensions: 12.9″ L x 12.4″ W x 2.5″ H (32.7 cm L x 31.5 cm W x 6.4 cm H)
  • Display: 12.1″/30.7 cm diagonal LCD (NTSC or PAL)
  • Architecture: All-digital broadband multi-frequency imagining
  • Dynamic range: Up to 165 dB
  • Gray scale: 256 shades
  • HIPAA compliance: Comprehensive tool set

Imaging Modes and Processing
Broadband, multi-frequency imaging

  • 2D/Tissue Harmonic Imaging/M-Mode
  • Velocity Color Doppler
  • Color Power Doppler
  • PW, PW Tissue Doppler, and CW
  • Doppler angle, correct after freeze

Image Processing

  • SonoADAPT Tissue Optimization
  • SonoHD Imaging
  • Advanced Needle Visualization
  • Dual Imaging, Duplex Imaging, 2x pan/zoom capability, Dynamic range and gain
  • Duplex Imagine
  • HD Technology

User Interface and Remappable Controls

  • Softkeys to drive advanced features
  • Programmable A and B keys: each can be assigned by the user for increased ease of use
  • Silicone splash resistant sealed QWERTY keyboard
  • Track pad with select key for easy operation and navigation
  • Doppler controls: angle, steer, scale, baseline, gain and volume
  • Image acquisition keys: review, report, Clip Store, save
  • Dedicated AutoGain and exam keys to allow quick activat‌ion
  • Color controls: size/ position, angle, scale, baseline and invert

Application-Specific Calculations

  • OB/GYN/Fertility
  • Vascular
  • CIMT (Carotid lntima Media Thickness)
  • Cardiac
  • Transcrania Doppler (TCD)

Onboard Image and Clip Storage/ Review

  • 8 GB internal Flash memory storage capability
    • Potential to store 30,000 images or 960 2-second clips
  • Clip Store capability (maximum single clip length: 60 seconds)
  • Clip Store capability via either number of heart
    cycles (using the ECG) or time base Maximum
    storage in ECG beats mode is 10 heart cycles Maximum storage in time base mode is 60
    seconds
  • Cine review up to 255 frame-by-frame images

Measurement Tools, Pictograms, and Annotations

  • 2D: Distance calipers, ellipses and manual trace
  • Doppler: Velocity measurements, pressure half time, auto and manual trace
  • M-Mode: Distance and time measurements, heart rate calculation
  • User-selectable text and pictograms
  • User-def‌ined, application-specif‌ic annotations
  • Biopsy guidelines

External Data Management and Wireless

  • SonoSite® Workf‌low Solutions (SWS):Streamlines exam management for billing, credentialing, archive & EMR Integration
  • PC/Mac export configuration
  • Export BMP, JPEG or DICOM images to a USB
    device
  • Storage capacity alert if internal storage memory is
    less than 10%

Connectivity

  • S-video (in/out) to VCR for record and playback
  • DVI output
  • Composite video output (NTSC/PAL) to VCR or video printer
  • Audio output
  • Integrated speakers
  • Ethernet or wireless image/data transfer
  • USB ports (2)
  • RS-232 transfer
  • DICOM® Image Management: Store, Print, Storage Commit, Modality Worklist, MPPS

Power Supply

  • System operates via battery or AC power
  • Rechargeable lithium-ion battery
  • AC: universal power adapter, 100-240 VAC, 50/60 Hz input, 15 VDC output

Edge Stand and Peripherals

  • Transducer and gel holders
  • Optional Triple Transducer Connect (TTC) to quickly activate transducers electronically
  • Optional foot switch

Optional peripherals:

  • Printers: Medical-grade black and white or color
  • External data input devices: Bar code reader
  • ECG module: 3-Iead ECG -works with standard
  • ECG leads and electrodes
  • External analog ECG input also available

System Applications & Reporting

  • Abdomen
  • Emergency Medicine
  • General Imaging
  • Intraoperative/ Interventional
  • Renal

Pain Management Imaging

  • Musculoskeletal (MSK)
  • Anesthesia
  • Orthopedic

Women’s Imaging

  • Advanced OB
  • Breast Imaging
  • Gynecology
  • Obstetrics

Cardiac Imaging

  • Cardiac Screening/ Survey

Small Parts

  • Breast
  • Testicle
  • Thyroid

Urology Imaging

  • Pelvis
  • Prostate

Vascular Imaging

  • Arterial
  • Carotid
  • IMT
  • Venous
  • Volume Flow

Structured Reporting

  • DICOM-Cardiac Structured Reporting
  • DICOM-Vascular Structured Reporting
  • DICOM-OB/GYN Structured Reporting

System Applications & Reporting

  • Abdomen
  • Emergency Medicine
  • General Imaging
  • Intraoperative/ Interventional
  • Renal

Pain Management Imaging

  • Musculoskeletal (MSK)
  • Anesthesia
  • Orthopedic

Women’s Imaging

  • Advanced OB
  • Breast Imaging
  • Gynecology
  • Obstetrics

Cardiac Imaging

  • Cardiac Screening/ Survey

Small Parts

  • Breast
  • Testicle
  • Thyroid

Urology Imaging

  • Pelvis
  • Prostate

Vascular Imaging

  • Arterial
  • Carotid
  • IMT
  • Venous
  • Volume Flow

Structured Reporting

  • DICOM-Cardiac Structured Reporting
  • DICOM-Vascular Structured Reporting
  • DICOM-OB/GYN Structured Reporting