Esaote MyLab 25 GOLD

    biosound-mylab25-ultrasound-system
    Esaote MyLab 25 GOLD Ultrasound

    More Than a Mobile System

    The Biosound MyLab 25 GOLD defines a new standard in premium performance mobile ultrasound. The system incorporates a powerfully redesigned platform for general imaging and shared services, offering high performance and reliability in a compact and portable package. MyLab 25 GOLD represents state-of-the-art technology and premium diagnostic ultrasound capabilities, ensuring extended modularity and upgradeability.

    Below is a generalized description of this systems technology, specifications, features, and options. The below may not reflect the features and options available on units in our inventory.

    The MyLab25®Gold represents state-of the-art technology and premium diagnostic ultrasound capabilities, ensuring extended modularity and upgradeability.
    Highlighted features of the MyLab25®Gold include:
    • An optional lightweight battery
    • A redesigned, user-friendly ergonomic keyboard with extended control panel function.
    • 15″ high-resolution TFT LCD
    • Two active imaging probe connectors
    • Application-dedicated, extended bandwidth probes with innovative ergonomic shape (Appleprobes)
    • TEI® – Tissue Enhancement Imaging
    • XView – real-time adaptive noise reduction algorithm
    • M-View – image compounding
    • VPan – eXtended field of view
    • Advanced OB/Gyn package:
      • A new 4D motorized probe for easy & fast 3D/4D acquisitions
      • X4D real-time technology for advanced 3D/4D OB/GYN imaging in volumetric scanning
    • Advanced vascular packages:
      • QIMT – Real time, radio frequency based CIMT measurement package
    • Transcranial Doppler, with reporting
    • Windows® platform
    • CD/DVD and USB 2.0 ports for transferring clinical data, PC Graphic standard and DICOM compliant
    • MyLab®Desk software package for viewing, clinical measurement, reporting and archiving; software provided at no additional cost
    Physical Dimensions
    • Closed: 35 W x 18 H x 49 D cm
    • Open/Working: 35 W x 43 H x 49 D cm
    • Weight: 10 kg (system only)
    Monitor
    • Tiltable 15″ XVGA LCD Monitor
    • Contrast Digital Adjustment
    Control Panel
    • LEDs Brightness Digital adjustment
    • Ergonomic Key Layout
    • Ergonomic and adjustable back lighting control panel
    • Primary controls easily accessible and logically grouped
    • Programmable keys
    • eTouch: Macro Recorder
    • SmarTouch: easy way to optimized system settings Trackball with two keys – PC mouse logic
    • Trackball with two keys – PC mouse Logic
    • Dedicated buttons to activate primary modalities:
      • B-Mode
      • M-Mode
      • 3D/4D
      • CFM
      • PW
      • CW
    • Direct multifunction knob to activate and control primary modalities:
      • Imaging Gain
      • Doppler Gain
    • Dedicated key for:
      • System on/off
      • End exam
      • General Setup Menu
      • Archive
      • Application measure
      • Generic Measure
      • Line/Update (in split modes)
      • Dual Imaging
      • Image/Clip Storage
      • Acquire (for advanced operations)
      • Auto Adjust
      • 8 TGC slide controls
    • Integrated Loudspeakers
    Enhanced Image Processing
    • Tissue Enhancement Imaging (TEI™)
    • XView algorithm
    • M-View
    Operative Modes
    • B-Mode (2D)
    • Colorize 2D, M-Mode and PW/CW
    • PW/CW Doppler
    • Non Imaging CW
    • CFM (Color Doppler)
    • Power Doppler
    • Directional Power Doppler (VeloPower)
    • TEI (Tissue Enhancement Imaging
    • ECG
    • CMM (Compass M – Mode)
    • TVM (Tissue Velocity Mapping)
    • TPView
    • MView on linear and convex probes
    • VPan (Panoramic View)
    • CnTI (Contrast Tissue Enhanced Imaging)
    • 3D/4D Imaging
    • One touch button image optimization in 2D, PW/CW
    Archiving Capabilities
    • Still image, Video clips (Full resolution)
    • Patient data, Annotations, body marks and measurements
    • Reports
    • Offline capability
    • Pause a study
    • Visual comparison saved images/clips archived images/clips
    • Compressed images and clips
    • Cine Memory: up to 1.000 frames
    • PC: > 2 GB
    • Local Drivers
      • Hard disk: 250 GB
      • DVD reader/writer
    • Internal Patient Database
    • User selectable filter for the database search
    • Still images and loops storage in DICOM formats
    • Real Time Archive capability for still frames and video clips
    • Stored data thumbnails always displayed onscreen
    • IHE Complaint
    • Annotation/Bodymark/Measurements capability on previously stored images
    Data Export
    • Standard output file formats (BMP, PNG, JPEG)
    • Native and DICOM formats
    • Clips formats:
      • AVI Codec: Microsoft MPEG4-V2 and Microsoft -Video1
      • Still frames: compressed (lossy, loss-less) and not compressed
      • Native and DICOM formats
    • Patient data, Annotations, Body marks and Measurements from the graphic overlays
    • Reports in PDF
    DICOM Connectivity MyLab25 system supports the following DICOM service classes:
    • Verification service class as the SCU and SCP
    • Modality Worklist management service class in the role of SCU
    • Modality Performed Procedure Step (MPPS) class in the role of SCU
    • Storage service class as a SCU
    • Storage Commitment service class as SCU
    • DICOM Print SCU
    • DICOM Query Retrieve
    • Cardiology (Adult, Pediatric, Neonatal)
    • Vascular
    • Contrast Imaging
    • Adult Transcranial
    • General Imaging (Neonatal, Pediatric, Adult)
    • Abdomen
    • Urology
    • Intraoperative/Interventional
    • Small Parts
    • Breast
    • OBGYN
    • Breast
    • Musculoskeletal
    • Women’s Healthcare
    Transducer types
    • Multifrequency Electronic Convex Array
    • Multifrequency Electronic Linear Array
    • Multifrequency Electronic Phased Array
    Transducers/Probes
    • LA523 | 13-4 MHz Linear Transducer
    • LA522 | 9-3 MHz Linear Transcuder
    • LA435 | 13-4 MHz Linear Transducer
    • LA332 | 11-3 MHz Wide Linear Transducer
    • CA430 | 8-1 MHz Curved Transducer
    • CA123 | 9-3 MHz MicroConvex Transducer
    • BC431 | 8-1 Volumetric Convex
    • BE1123 | 9-3 Volumetric Endocavity
    • EC1123 | 9-5 MHz EndocavityTransducer
    • TRT33 | Bi-plane Transducer
    • PA230 | 4-1 MHz Phased Array Transducer
    • PA122 | 6-2 MHz Phased Array Transducer
    • PA121 | 6-2 MHz Phased Array Transducer
    • PA023 | 11-4 MHz Phased Array Transducer
    • PA240 | 4-1 MHz Phased Array
    • IOE323 | 13-44-1 MHz Intraoperative Transducer
    • LP323| 13-4 MHz Laparoscopic Linear
    • TEE132 | 8-3 MHz Pediatrics TEE Phased Array
    • TEE022 | 8-3 MHX Adult TEE Phased Array
    • 2 MHz CW | Pencil Probe
    • 5 MHz CW | Pencil Probe
    • HF CW | Pencil Probe