Siemens Sonoline G40

    siemens-sonoline-g40-ultrasound-system1
    Siemens Sonoline G40

    Comprehensive Capabilities in a Compact Size.

    The Sonoline G40 ultrasound system brings the benefits of Siemens core technology migration to an entirely new level of diagnostic performance and workflow efficiency, all in an ultra-portable system that meets your clinical needs. With a comprehensive range of features including color Doppler and pulsed-wave Doppler capabilities, the G40 system sets a new performance standard in the world of compact, mobile, color Doppler ultrasound systems.

    Below is a generalized description of this systems technology, specifications, features, and options. The below may not reflect the features and options available on units in our inventory.

    The SONOLINE G40™ ultrasound system brings the benefits of Siemens core technology migration to an entirely new level of diagnostic performance and workflow efficiency, all in an ultra-portable system that meets your clinical needs. With a comprehensive range of features including color Doppler and pulsed-wave Doppler capabilities, the G40 system sets a new performance standard in the world of compact, mobile, color Doppler ultrasound systems.

    • Migration of Siemens all-digital signal processing technology ensures best-in-class image quality for higher diagnostic confidence
    • State-of-the-art beam forming architecture advances clinical capabilities with SynAps™ synthetic aperture technology for improved penetration and focus, parallel B-mode and color signal processing and phased array imaging functionality
    • AutoColor technology provides single-step color Doppler optimization and auto trace functionality offers easy acquisition and quantification of color and Doppler studies
    • Patented Hanafy lens acoustic technology enables clear differentiation of near-field structures and reduces far-field beam spread
    • Imaging frequencies from 2–13 MHz provide superb support for a wide range of clinical applications
    • Virtual Format Imaging increases anatomic information with a touch of a button, providing a selection of linear, trapezoidal and steered 2D imaging formats
    • Open system architecture enables easy integration of advanced capabilities including phase inversion Tissue Harmonic Imaging (THI) and 3D imaging
    • Comprehensive DIMAQ-IP integrated workstation allows instantaneous storage, review and quantification of complete ultrasound studies
    • Compact, lightweight system with small footprint provides virtually effortless mobility and easy micropositioning in tight workspaces
    • Intuitive user interface and familiar SONOLINE control panel layout advance workflow efficiency and clinical throughput
    • Compact system design combined with color Doppler capability supports portable examinations without compromise
    • TGO™ tissue grayscale optimization technology provides instantaneous, one-button image optimization
    • Integrated documentation peripherals and onboard storage conveniently offer easy access to accessories needed to complete a
    • comprehensive exam
    • DIMAQ-IP integrated workstation supports capture and review of entire clinical studies in any environment, along with exportation of exams to CD
    • Plug-and-play connectivity solutions allow easy integration into DICOM-enabled networks and PC-based workstations for efficient export of exam data
    • Modern system design with integrated cable management and three transducer ports provides excellent protection during transport

    System Specifications

    • Height: 136.0 cm (53.5 inch)
    • Width: 51.8 cm ( 20.4 inch)
    • Depth: 85.1 cm (33.5 inch)
    • Weight: 93 kg (205 pounds) without OEM’s

    Monitor

    • MultiSync, 15-inch, high resolution, progressive
      scan (non-interlaced)
    • 800 x 600 pixel display matrix with a recordable
      image area of 800 x 600 pixels (SVGA)
    • Monitor tilt of 15 degrees up, 10 degrees down
      and swivel of 180 degrees
    • Digital on-screen display brightness and contrast
      controls with factory default presets
    • Energy Saving Display Power Management
    • 4 levels of illumination intensity: Off, 1, 2, 3

    User Interface

    • Intuitive PC-based operating principles
      User-centric control panel with HomeBase layout
    • On/Off tasklight and back-lit illumination of control
      panel
    • Variable brightness indicates active state of
      function keys
    • On Screen Menu (OSM) provides easy and
      immediate access to secondary imaging controls
    • Easy accessible, full size QWERTY keyboard for text
      entry, function keys and system programming
    • Wrist support to help reduce operator repetitive
      stress injuries
    • Up to 32 QuickSet user-programmable system
      parameters. Allow users to program system
      parameters for individual transducer/application
      settings. QuickSet parameters combine all preferred
      imaging mode parameters, annotation text and
      measurements into one user preset

    Operating / Display Modes

    • 2D imaging in fundamental and harmonic modes
    • M-mode
    • Color Doppler Velocity mode
    • Power Doppler mode
    • PW Pulsed Wave spectral Doppler mode
    • Duplex Mode
    • Triplex mode
    • Flexible combination of imaging modes in side-by- side Dual and Dual Select in real-time, and digital cine replay
    • Selectable split screen display formats in 2D or 2D/color with M-mode and/or spectral Doppler mode: top-bottom or side-by-side in real-time and digital cine replay

    Hard Drive

    • Internal 40 GB Hard Drive for patient database
      management
    • Allows storage of patient studies that include
      images, reports and measurements
    • Image storage capacity up to 120,000 images; color
      or black/white

    CD-R/W Drive

    • Support either 650 MB or 700 MB read/write CD-R
    • Allows storage and archiving of complete patient
      studies including still images, reports and
      measurements
    • Storage capacity dependent upon patient study
      Size
    • Export of images in TIFF format, DICOM exchange
      Media (requires DICOM connectivity option)
      Individual selection of single study for transport

    Power Supply

    • 100-120/200-240 VAC, 50/60 Hz

    Patient Study Management
    Replay of digitally stored images in a selectable 1-up, 4-up, 9-up or 16-up screen format. The patient study screen allows for study selection, search, and deletion or for export to CD-R.

    • Internal 40 GB hard drive for patient data
      management
    • CD-R/W drive for 650 and 700 MB CD-R provides
      patient study archiving
    • Hard drive capacity:
      • Approximately 120,000 b/w and color images
    • Storage and retrieval of frozen static images
    • Storage and retrieval of reports
    • Instant dial-in and replay of static images in 1-up
      screen format
    • Supports Measurements and Calculations on current,
      as well as on saved and retrieved images
    • Export of patient studies from hard drive to CD-R/W
      drive. Studies can be individually selected
    • Images are exported in PC compatible TIFF format
      or DICOM format (optional)
    • M-mode Still Frame Scroll and Store
    • PW Spectral Doppler Still Frame Scroll and Store
    • Patient database sorting by Name, ID, Study Date
      and Exam type

    General Imaging

    • Abdomen
    • Renal

    Pain Management Imaging

    • Musculoskeletal (MSK)
    • Orthopedic
    • Podiatry

    Women’s Imaging

    • Breast Imaging
    • Gynecology
    • Obstetrics
    • Reproductive Medicine (IVF)

    Cardiac Imaging

    • Cardiac Screening/ Survey
    • TEE (Option)

    Small Parts

    • Breast
    • Testicle
    • Thyroid

    Urology Imaging

    • Pelvis
    • Prostate

    Vascular Imaging

    • Arterial
    • Carotid
    • Venous

    Transducers/ Probes:

    • Linear Array 5-13 MHz*
    • Curved Array 2-5 MHz
    • Phased / Sector Array 2-8 MHz*
    • Endocavity 4-9 MHz
    • Endovaginal 4-9 MHz

    Cardiac Transducers/ Probes:

    • Adult Cardiac 2-4 MHz
    • Fetal Cardiac 4-8 MHz

    Transducer Ports

    • Two active universal transducer ports that support Phased Array, Curved Array and Linear Array transducers
    • One parking port
    • Electronic transducer selection (instantaneous switching between transducers)
    • Industrial design provides easy access to the transducer ports

    Transducers:

    • VF13-5
    • VF10-5
    • CH5-2
    • EC9-4
    • EV9-4
    • P8-4
    • P4-2