SonoSite MircoMaxx

sonosite-micromaxx-ultrasound-machine
SonoSite MicroMaxx Ultrasound

Big Machine Performance in a Hand-Carried Unit

The portable SonoSite MicroMaxx ultrasound system has purpose-built software and proprietary ASIC design yielding high-quality images with speed and reliability while efficiently operating on either AC or battery power.

Below is a generalized description of this systems technology, specifications, features, and options. The below may not reflect the features and options available on units in our inventory.

MicroMaxx
Designed to make your job easier, faster and more accurate, the MicroMaxx® ultrasound tool makes point-of-care ultrasound an affordable reality. It offers impressive image quality. Wireless data transfer. Extreme durability.
Big Machine Performance in a Hand-carried Unit
MicroMaxx’s purpose-built software and proprietary ASIC design yield high-quality images with speed and reliability while efficiently operating on either AC or battery power.
MicroMaxx Goes Anywhere You Need It
From busy offices and big-city hospitals to critical-care situations where seconds count, the MicroMaxx system boots up within 15 seconds. This easily-carried device gets medical professionals into-and out of-tight spaces fast.
Embedded Software Means Solid Reliability
The MicroMaxx system software is hard-wired and purpose-built for faster boot-up times, faster digital image processing, and the ability to run for a long time. Power is efficiently used, extending battery life for use wherever needed.
Chip Fusion Technology
SonoSite’s proprietary Chip Fusion technology enables advanced, cart-based image resolution in a hand-carried unit by integrating digital signal processing and multiple ultrasound functions into a custom ASIC microchip to deliver unprecedented performance without the size, weight, and cost of conventional systems.
Clinical Utility

  • The MicroMaxx system comes with a wide range of ultrasound transducers for multiple clinical applications.
  • The MicroMaxx system also includes SonoCalc® IMT, which is proprietary edge-detection software that enables clinicians and cardiology specialists to quickly and easily measure intima-media thickness of the carotid artery for assessment of arterial wall disease progression and cardiovascular risk
Durability
SonoSite products and technology deliver proven reliability and durability in conventional medical settings, as well as some far more challenging environments, such as supporting rescue operations following natural disasters. Extensive quality controls, such as “drop testing,” ensure that SonoSite products continue to set the industry standard for both reliability and durability.
5-Year Warranty
MicroMaxx’s reliability and durability are backed by a 5-year warranty, an industry first, far exceeding warranties available on competing products.
From “Off” to Scanning in Just Seconds
This is vitally important in many medical situations where seconds really do count – whether getting crucial diagnostic information in an emergency or making the best use of time in a hectic daily schedule.

System Specifications

  • Weight 7.7 lb (3.5 kg) (transducer attached)
  • Dimensions 11.8″ L x 10.8″ W x 3.1″ H (30.2 cm L x 27.7 cm W x 8.0 cm H)
  • Display 10.4″ (26.4 cm) diagonal LCD (NTSC or PAL)
  • Architecture All-digital broadband
  • Number of channels 128 channels
  • Dynamic range Up to 165 dB
  • Gray scale 256 shades
  • HIPAA compliance Comprehensive tool set

Imaging Modes

  • 2D/velocity color Doppler/color power Doppler/M-mode/PW and CW Doppler
  • Dual imaging
  • M-mode/Duplex Imaging:
  • 3 sweep speeds
  • 1/2:1/2, 1/3:2/3 and full-screen options
  • 2X pan/zoom
  • Tissue harmonic imaging
  • Broadband, multifrequency imaging
  • 1-8 focal zones
  • Image Processing:
  • Compression, contrast enhancement, persistence,
    dynamic range and gain

User Interface

  • Soft keys to drive advanced features
  • Delta key: user-assigned functions for increased ease of use
  • Alphanumeric QWERTY keyboard
  • Track pad with select key for easy operation and navigation
  • Doppler/M-mode controls: angle, steer, scale, baseline, gain and volume
  • Image acquisition keys: review, rep0it, VCR, clip store

System Parameter

  • System dynamic range: approximately 140 dB
  • Frame rate: up to 100 frames/second

Onboard Image and Clip Storage/ Reviewer

  • Store up to 10,000 images with a 1 GB CompactFlash card
  • Cine: review up to 220 frame-by-frame images
  • Store up to 700 clips with a 4 GB CompactFlash card

External Video Management

  • S-video (in/out) to VCR or DVD for record and playback
  • RGB output to external LCD display
  • Composite video output (NTSC/PAL) to VCR, video printer or external LCD display
  • Audio output
  • Integrated speakers

Measurement Tools

  • 2D
  • Distance calipers
  • Ellipse for area and circumference measurements
    Doppler
  • Velocity measurements, RI & S/D ratio
  • Volume flow calculation
  • M-mode
  • Distance and time measurements
  • Heart rate calculation
  • User-selectable text and body markers
  • Application-specif‌ic text via function keys
  • Biopsy guidelines

Power

  • System operates via battery or AC power
  • Rechargeable lithium-ion battery
  • AC: universal power adapter, 100-240 VAC, 50/60 Hz input, 15 VDC output

Mobile Docking Station and Peripheral

  • MDS — Convenient Workstation:Storage for fully Integrated printer, VCR and/or DVD
  • Transducer holder and storage
  • Optional Triple Transducer Connect allows the user to quickly activate transducers electronically
  • Optional 12.1″ (30-7 cm) (diagonal) monitor
  • MDS Lite — Convenient Workstation: Storage for fully integrated printer, VCR or DVD
  • Transducer holder and storage
  • Optional Triple Transducer Connect allows the user
    to quickly activate transducers electronically

Printers

  • Printers: Medical-grade black and white or color
  • External storage devices: MedicaI- grade VCR or DVD
  • ECG module23-lead ECG – works with standard
  • ECG leads and electrodes

System Applications & Reporting

  • Abdomen
  • Emergency Medicine
  • General Imaging
  • Intraoperative/ Interventional
  • Renal

Pain Management Imaging

  • Musculoskeletal (MSK)
  • Anesthesia
  • Orthopedic
  • Podiatry

Women’s Imaging

  • Advanced OB
  • Breast Imaging
  • Gynecology
  • Obstetrics

Cardiac Imaging

  • Cardiac Screening/ Survey

Small Parts

  • Breast
  • Testicle
  • Thyroid

Urology Imaging

  • Pelvis
  • Prostate

Vascular Imaging

  • Arterial
  • Carotid
  • IMT
  • Volume Flow
  • Venous

Structured Reporting

  • DICOM-Cardiac Structured Reporting
  • DICOM-Vascular Structured Reporting
  • DICOM-OB/GYN Structured Reporting

Transducers/ Probes * (Displayed MHz Range Includes Multiple Transducers)

  • Linear Array 5-13 MHz*
  • lntraoperative / Hockey Stick 5-13 MHz*
  • Curved Array 2-5 MHz
  • Micro-Convex 5-8 MHz
  • Phased/ Sector Array 1-5 MHz
  • Endovaginal 5-8 MHz
  • Endorectal 5-8 MHz
  • Veterinary (Equine) 3-8 MHz

Cardiac Transducers/ Probes:

  • Adult Cardiac 1-5 MHz*
  • Pediatric Cardiac 4-8 MHz
  • Pencil 2 MHz
  • TEE 3-8 MHz

Transducers:

  • L25e
  • L38e
  • HFL38
  • SLA
  • SLT
  • ICTe
  • C8
  • C11e
  • P10
  • P17
  • C60e
  • TEE
  • D2